Search results
Jump to navigation
Jump to search
Create the page "Alignment" on this wiki! See also the search results found.
- =Subtomogram alignment and averaging= ...eed an initial reference (which will later be refined during the iterative alignment). Here, we create such an initial reference by manually align a few particl15 KB (2,427 words) - 18:27, 3 September 2021
- ...is always useful to use the produced {{t|crop.tbl}} table to initialize an alignment project, as it contains the identities of the particles actually on the dat ...6. Including the shifts is crucial if the table expresses the result of an alignment project, as the final ''xyz'' position of the particles will be the additio5 KB (787 words) - 13:49, 23 May 2018
- ...e tomograms through the ''Dynamo'' catalogue and developing strategies for alignment projects to reach a reasonable structure from a set of tomograms. You will ...crop points and their orientations (when visualizing actual results of an alignment project use option '' 'corrected_oriented_positions'' ' instead of the one22 KB (3,572 words) - 13:13, 18 August 2021
- ...ased tilt series alignment | walkthrough on command line based tilt series alignment]] shows how to operate this procedure through the command line. = Creating an alignment workflow=21 KB (3,158 words) - 16:09, 6 September 2021
- ...ased tilt series alignment | walkthrough on command line based tilt series alignment]] shows how to operate this procedure through the command line. = Creating an alignment workflow=21 KB (3,161 words) - 23:05, 5 August 2021
- ...subunits of interest with relation to the center of the average. Then, the alignment [[table]] that produced the average can be used to produce a ''subboxed tab2 KB (374 words) - 16:54, 26 October 2017
- ...oductionAlignmentProjects.pdf tutorial on] the basic concept in ''Dynamo'' alignment: the ''project''.2 KB (304 words) - 10:09, 19 July 2017
- ...action that ''Dynamo'' will execute after each iteration during a project alignment.7 KB (1,043 words) - 18:07, 9 March 2017
- ...icles. Thus, you need a [[data folder]] and a [[table]] that describes the alignment.3 KB (424 words) - 18:03, 28 March 2020
- :-Alignment of axes in orthogonal orientations3 KB (423 words) - 16:23, 27 April 2017
- ...aging, some steps in [[PCA]] analysis, manual management of models. Even [[alignment project]]s with modest number of particles can be reasonably executed on a ...tion, cropping particles, and any preprocessing related to the creation of alignment project. Once the project has been created (as a folder and an execution sc6 KB (966 words) - 14:34, 24 January 2022
- Masks are initiated to default values. This means spherical masks for alignment and classification masks, and full cubes for smoothing and fourier mask of Then select the number of available cores for alignment and averaging.10 KB (1,461 words) - 19:12, 27 November 2017
- ...describes the basics including particle picking, initial model generation, alignment, averaging and classification or particles. ''Dynamo'' has a standalone to ...:StartersGuideParticlesUnaligned.png|thumb|center|400px| Particles without alignment (<tt>table</tt> is switched off).]]24 KB (3,775 words) - 15:39, 6 September 2021
- ...oductionAlignmentProjects.pdf tutorial on] the basic concept in ''Dynamo'' alignment: the ''project''.3 KB (397 words) - 08:01, 5 September 2018
- ...rder to make easy to keep track on the processing steps already performed (alignment, reconstruction), the location of the intermediate results, and their bindi In this example, we assume that you are using <tt>imod</tt> for tomographic alignment and reconstruction of each tilt series. The raw data is stored in a tree be8 KB (1,277 words) - 18:14, 16 May 2017
- ...to ease computations, a binning order is passed to the [[Alignment project|alignment]] or classification project.8 KB (1,292 words) - 17:50, 6 February 2020
- ...will depend on the reconstruction program you used, and how it handled the alignment. Lets assume a <tt>ftype</tt> 1 (i.e., column 13 of table will be one). In3 KB (548 words) - 11:41, 3 April 2020
- This shell is "activated" and can then be used to run [[alignment project]]s or to initiate an interactive session using the ''Dynamo'' [[Dyn3 KB (551 words) - 14:01, 22 June 2018
- ...step and set the "Angle offset" and "Z shift" to zero. 2) Go to the "Fine Alignment" step and set the two values to zero too. Do ''not'' go back to the "Tomogr4 KB (646 words) - 14:34, 9 April 2019
- ...n be used directly by ''Dynamo'' to operate an extraction and a subsequent alignment. ...s that are poorly defined still have a chance to get driven by a posterior alignment to the center of the box. If we initialize some variables:18 KB (3,099 words) - 13:19, 18 August 2021