Difference between revisions of "Framework for estimation of membrane thickness"

From Dynamo
Jump to navigation Jump to search
Line 32: Line 32:
 
</nowiki>
 
</nowiki>
  
Your can create a compact version of this cell array:
+
You can create a compact version of this cell array:
 
  <tt>pac  = mbg.cellCompact(pa);</tt>
 
  <tt>pac  = mbg.cellCompact(pa);</tt>
  

Revision as of 09:44, 4 May 2017

This framework is more useful in plastic sections. The premise is that an alignment project has been created to fix the position an orientation of a set of points of interest inside a membrane. In a later stage, we want to get an estimation on the distance between the membrane layers on each particle. This task can be performed through a multireference analysis, but it can also be approached with an analysis a posteriori as sketeched here.

Reading the particles

The easiest way to bring particles aligned by a project is through the use of the dpkdata.Reader object. If you store the table and data folder of your project in myTable and myData

r = dpkdata.Reader();
r.setSource('table', myTable,'data',myData);

you can access the particles throught the getParticle method:

p = r.getParticle(12,'align',1); 

gets the particle with tag 12 as a variable p in the workspace. You can also read all the particles as a matlab cell array through

pa = r.getParticle('*','align',1); 

Note that pa may have empty spaces: only the positions with an actual particle tag in the data folder will be occupied. For instance, if you don't have a particle labelled wiht 4 in your data folder, you will see it as.

>> pa

pa  =

  1×194 cell array

  Columns 1 through 5

    [96×96×96 double]    [96×96×96 double]    [96×96×96 double]    []    [96×96×96 double]

  Columns 6 through 9

    [96×96×96 double]    [96×96×96 double]    [96×96×96 double]    [96×96×96 double]


You can create a compact version of this cell array:

pac  = mbg.cellCompact(pa);
>> pac

us =

  1×193 cell array

  Columns 1 through 4

    [96×96×96 double]    [96×96×96 double]    [96×96×96 double]    [96×96×96 double]

  Columns 5 through 8

   [96×96×96 double]    [96×96×96 double]    [96×96×96 double]    [96×96×96 double]

Creating a distance filter

We first create a set of filters that model the distance between the two layers of the membrane.

 t = dpkfw.mdm.templateSeries('size',16,'thickness',1,'distance',[3:7]); 

Here, t is a cell array, containing 5 volumes of 16x16x16 pixels each. Each volume contains a "model" of a membrane.

Applying the filters onto a particle

If you have your particle in the Matlab/Dynamo workspace with name p you can type.

o = dpkfw.mdm.bestFilteringDistance(p,'templates',t);

The output structure o contains several fields with different output aspects.

>> o

o = 

  output with properties:

        ok: 0
    report: {}
        cc: {[1×1 struct]  [1×1 struct]  [1×1 struct]  [1×1 struct]  [1×1 struct]}
     ccmax: [0.3385 0.3321 0.7576 0.3305 0.3393]


In particular, ccmax is telling you the response of the particle to each filter. In this case, the largest response is to the third filter in t, corresponding to an space of 5 pixels.


Loop on particles and distance histogram

Now you can put all these elements together and compute the largest response for each particle.