Difference between revisions of "Considerations for tomogram positioning in IMOD"

From Dynamo
Jump to navigation Jump to search
(Created page with "During tomogram reconstruction in [https://bio3d.colorado.edu/imod/ IMOD] at some point the dimensions of the final tomogram are calculated in the "tomogram positioning" step....")
 
Line 1: Line 1:
During tomogram reconstruction in [https://bio3d.colorado.edu/imod/ IMOD] at some point the dimensions of the final tomogram are calculated in the "tomogram positioning" step. In this step, we recommend to keep the x-axis tilt at zero and to leave enough room above and below the sample in the tomogram. Keeping the x-axis tilt at zero facilitates the interpretation of the tomograms, since the z-axis corresponds to the direction of the electrons. It also saves us from adapting the [[Indicating_the_missing_wedge | missing wedge]] mask at later steps. Leaving enough space at the top and bottom of the sample in the tomogram is necessary to crop subvolumes from sample that is close to the ice surfaces:
+
During tomogram reconstruction in [https://bio3d.colorado.edu/imod/ IMOD], the dimensions of the final tomogram need to be calculated in the "tomogram positioning" step. In this step, we recommend to keep the x-axis tilt at zero and to leave enough room above and below the sample in the tomogram. Keeping the x-axis tilt at zero facilitates the interpretation of the tomograms, because only then the z-axis corresponds to the direction of the electrons. It also saves us from adapting the [[Indicating_the_missing_wedge | missing wedge]] mask at later steps. Leaving enough space at the top and bottom of the sample in the tomogram is necessary because it allows Dynamo to crop subvolumes from sample that is close to the ice surfaces, as illustrated in the figure below:
  
  
Line 5: Line 5:
  
  
To keep the x-axis tilt at zero and to keep the tomogram thick enough we follow the following steps. First we choose a fairly large thickness for the sample tomogram (the sample tomogram will just be used to set the boundaries, it has not the final tomogram size). In the example below, an initial thickness of 4000 pixels was chosen:
+
To keep the x-axis tilt at zero and to keep the tomogram thick enough we need to proceed as follows. First we choose a fairly large thickness for the sample tomogram (the sample tomogram will just be used to set the boundaries, it has not the final tomogram size). In the example below, an initial thickness of 4000 pixels is chosen. We also select a binning level of 4 or 8 to save computing time.
  
  
  [[File:tomopitch_parameters.png|thumb|center|300px| Tomopitch parameters. The sample tomogram thickness is set to 4000 and the binning to 8. After running tomopitch make sure the x-axis tilt is 0.0. ]]
+
  [[File:tomopitch_parameters.png|thumb|center|300px| Tomopitch parameters. The sample tomogram thickness is set to 4000 and the binning to 8. After running tomopitch (“compute Z shift & pitch angles”), make sure that the x-axis tilt is still 0.0. ]]
  
  
We also select a binning level of 4 or 8 to save computing time. After we create the sample tomogram we open it to set the boundaries. Here we do not follow the IMOD tutorial but just stay in the normal 3dmod view and set the lower and upper boundaries as shown below. This will prevent the introduction of any x-axis tilt. It is important that in this step we leave enough space above and below the sample. We should be very generous with that (as explained in the first figure). After saving the model and clicking on “compute Z shift & pitch angles” there should be displayed a new z-shift and final tomogram thickness but the x-axis tilt should be 0.0.
+
After we create the sample tomogram we open it to set the boundaries. Here we do not follow the IMOD tutorial but just stay in the normal 3dmod view and set the lower and upper boundaries as shown in the figure below. This will prevent the introduction of any x-axis tilt. It is important that in this step we leave enough space above and below the sample. We should be very generous with that (as explained in the first figure). After saving the model and clicking on “compute Z shift & pitch angles”, there should be displayed a new z-shift and final tomogram thickness, but the x-axis tilt should still be 0.0.
  
  [[File:tomopitch_limits.jpg|thumb|center|600px| Using the sample tomogram, the boundaries are set in 3dmod. Move down in z-direction until you are enough below the sample and mark 3 contours with 2 points each as shown. Move up until you are enough above the sample and do the same. You should have now 6 contours with 2 points each. Save and close.]]
+
 
 +
  [[File:tomopitch_limits.jpg|thumb|center|600px| Using the sample tomogram, the boundaries are set in 3dmod. Left: Move down in z-direction until you are enough below the sample and mark 3 contours with 2 points each as shown. Right: Move up until you are enough above the sample and do the same. You should have now 6 contours with 2 points each. Save and close.]]

Revision as of 15:45, 31 January 2019

During tomogram reconstruction in IMOD, the dimensions of the final tomogram need to be calculated in the "tomogram positioning" step. In this step, we recommend to keep the x-axis tilt at zero and to leave enough room above and below the sample in the tomogram. Keeping the x-axis tilt at zero facilitates the interpretation of the tomograms, because only then the z-axis corresponds to the direction of the electrons. It also saves us from adapting the missing wedge mask at later steps. Leaving enough space at the top and bottom of the sample in the tomogram is necessary because it allows Dynamo to crop subvolumes from sample that is close to the ice surfaces, as illustrated in the figure below:


Left: The tomogram is too thin and subvolumes at the upper/lower sample border cannot be cropped. Right: Enough space on top and bottom of the tomogram allows cropping of volumes anywhere in the sample.


To keep the x-axis tilt at zero and to keep the tomogram thick enough we need to proceed as follows. First we choose a fairly large thickness for the sample tomogram (the sample tomogram will just be used to set the boundaries, it has not the final tomogram size). In the example below, an initial thickness of 4000 pixels is chosen. We also select a binning level of 4 or 8 to save computing time.


Tomopitch parameters. The sample tomogram thickness is set to 4000 and the binning to 8. After running tomopitch (“compute Z shift & pitch angles”), make sure that the x-axis tilt is still 0.0.


After we create the sample tomogram we open it to set the boundaries. Here we do not follow the IMOD tutorial but just stay in the normal 3dmod view and set the lower and upper boundaries as shown in the figure below. This will prevent the introduction of any x-axis tilt. It is important that in this step we leave enough space above and below the sample. We should be very generous with that (as explained in the first figure). After saving the model and clicking on “compute Z shift & pitch angles”, there should be displayed a new z-shift and final tomogram thickness, but the x-axis tilt should still be 0.0.


Using the sample tomogram, the boundaries are set in 3dmod. Left: Move down in z-direction until you are enough below the sample and mark 3 contours with 2 points each as shown. Right: Move up until you are enough above the sample and do the same. You should have now 6 contours with 2 points each. Save and close.